Resolution of Paragon Active Assurance measurement data¶
Time series of Paragon Active Assurance measurement data are stored in a round-robin database, where older data is progressively consolidated into lower resolutions.
Resolution for monitoring sessions¶
In each of your monitoring sessions, the Test Agents periodically collect measurement data in 10-second intervals, then compile the results into individual measurement reports and send them to the Paragon Active Assurance server. The measurement data can be said to have a “resolution” of 10 seconds.
In the database, the 10-second resolution is retained for data from the last 12 hours. Older data is aggregated as indicated in the following table:
Timeframe |
Resolution |
---|---|
12 hours |
10 seconds |
2 days |
1 minute |
1 week |
5 minutes |
1 month |
20 minutes |
1 year |
4 hours |
Resolution for tests¶